FitLife
  • # 6, De Fonseka Place, Colombo - 04, Sri Lanka
  • |   +94 712 308 883
  • +94 112 590 498

Available Items.

  • 2.1A/24V DC (S50-24)
  • 4.5A/24V DC (S10-24)
  • 6.5A/24V DC (S150-24)

Model

 

Specification

S-50-5

S-50-12

S-50-15

S-50-24

DC Output voltage

5V

12V

15V

24V

Output voltage range(Note:2)

±2%

±1%

±1%

±1%

Rated output current

10A

4.2A

3.4A

2.1A

Output current range

0~10A

0~4.2A

0~3.4A

0~2.1A

Wave and noise(Note:3)

75mVp-p

60mVp-p

60mVp-p

50mVp-p

Inlet stability(Note:4)

±0.5%

±0.5%

±0.5%

±0.5%

Load stability(Note:5)

±1%

±0.5%

±0.5%

±0.5%

DC output power

50W

50.4W

51W

50.4W

Efficiency

71%

78%

78%

80%

Adjustable range for DC voltage

+10,-5%

±10%

±10%

±10%

AC input voltage range

85~132VAC/170~264VAC selected by switch 47~63Hz,240~370VDC

Input current

1.3A/115V 0.65A/230V

AC Inrush current

Cold-start current 18A/115V 36A/230V

Leakage current

<0.5mA/240VAC

Overload protection

105%-150% Type: pulsing hiccup shutdown Reset: auto recovery

Temperature coefficient

±0.03%/°C(0~50°C)

Setup, rise, hold up time

200ms, 100ms, 30ms

Vibration

10~500Hz, 2G 10min,/1 cycle. Period for 60min,Each axes

Withstand voltage

I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

Isolation resistance

I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC

Working temperature and humidity

-10°C~+60°C(Refer to output load derating curve),20%~90%RH

Store temperature and humidity

-20°C~+85°C,10%~95%RH

Overall dimension

159X97X38mm (L*W*H)

Weight

0.5kgS

Safety standards

Meet UL 1012 requirement(Not apply for the mark)

 

 

© 2024 City Electrical Company. All Rights Reserved |Powered By ITMART